China BRICE Solar PV+8613738639386 [email protected]
For residential use
Solar module PERC - 200Wp Features:
Quick installation, flexible, soft, lightweight, as well as can be used in a variety of scenarios.
Main Performance Characteristics
Cells: 56 (Monocrystalline M10 cells)
Back panel: White
No frame
Output power: 200W
Product Warranty: 10 years
Power Warranty: 25 years
Maximum efficiency: 18.3 percent
24% lighter than conventional models
Power tolerance : 0~+5W
Solar Module Installation Schematic
Step 1
Fix the solar panel with strap to the balcony.
Step 2
Follow the first step and fix all the solar panels.
Step 3
Connect micro-inverter.
Step 4
Connect extension cable and plug in power supply.
Note: Please consult the technical engineers for detailed installation steps. The above pictures are only for reference.
CETC-200M(LB) /56 Balcony Solar System
Component
1 Flexible Solar Panel * 4
2 Micro-inverter * 1
3 AC Cable * 1
4 PV Cable 4m * 4
5 Fixing strap * 64
Panel Packaging(2 pieces / set) |
||
Container |
20’GP |
40’HQ |
Sets Per pallet |
42 |
49 |
Sets per container |
336 |
882 |
PV inverter (1 box / set) |
||
Container |
20’GP |
40’HQ |
Boxs per pallet |
120 |
120 |
Boxs per container |
1920 |
4320 |
Note: Container transport packaging method.
Electrical Characteristics |
|
Module Type |
CETC-200M(LB) / 56 |
Rated maximum Power(Pmax) |
200W |
Power Sorting |
(0,+4.99) |
Current at Pmax(lmp) |
13.0A |
Voltage at Pmax(Vmp) |
15.4V |
Short-circuit Current(lsc) |
13.6A |
Open-circuit Voltage(Voc) |
19.4V |
Power Production Tolerance |
±3% |
Short-circuit Current Tolerance |
±5% |
Open-circuit Voltage Tolerance |
±5% |
All technical data measured at STC:1000@/m2AM 1.5,25℃
Mechanical Characteristics |
|
Weight |
3.4kg/m2 |
Dimension |
1380 * 790 * 5 mm |
Maximum System Voltage |
600 /1000/1500V |
Maximum series Fuse Rating |
15/25A |
Cell Technology |
Mono-Si |
Fire Rating |
Class C |
Output | AC |
|||
Max AC Output Power(Wp) |
600 |
|
|
Nominal Power Grid Voltage(Vac) |
240 |
208 |
230 |
Allowable Power Grid Voltage(Vac) |
211-264 |
183-229 |
Configurable |
Allowable Power Grid Frequency(Hz) |
59.3-60.5 C |
|
Configurable |
THD |
<3% at rated power |
||
Power Factor (cos phi, fixed) |
>0.99 at rated power |
||
Rated Output Current (Aac) |
2.50 |
2.88 |
2.61 |
Current (inrush, peak and duration) |
24A, 15us |
||
Nominal Frequency (Hz) |
60 |
60 |
50 |
Maximum Output Fault Current (Aac) |
4.6A peak |
||
Maximum Output Overcurrent Protection (Aac) |
10 |
||
Maximum Number of Units per Branch (20A) All NeC adjustment factors have been considered |
7 |
6 |
6 |
Input | DC |
|
Max Recommended PV Power (Wp) |
450*2 |
Max DC Open Circuit Voltage(Vdc) |
60(80V customized) |
Max DC Input Current(Adc) |
14*2 |
MPPT Tracking Accuracy |
>99.5% |
MPPT Tracking Range(Vdc) |
22-55 |
Lsc PV (absolute maximum)(Adc) |
18*2 |
Maximum Inverter Backfeed Current to the Array(Adc) |
0 |
System Efficiency |
|
Weighted Averaged Efficiency(CEC) |
96.5% |
Night Time Rate Loss(Wp) |
0.11 |
One step to find us,we will respond within 24 hours
More Contact Details
008613738639386
[email protected]