China BRICE Solar PV+8613738639386 [email protected]



The Thinkpower S-series single-phase S1000TL-S6000TL inverters, with a power range of 1kW-6kW, are compact residential grid-connected solar inverters designed to provide home users with a comfortable and convenient user experience and a highly efficient and energy-saving solar power generation system. They feature a large, clear LCD display, support remote settings, and can be easily operated graphically via applications and web pages. They also support multiple communication methods including Wi-Fi, P2P, LAN, GPRS, and RS485.
Load consumption monitoring
IP65 protection
Power export limit
Big LCD display
Smart Control Monitoring
Users can check 24-hour load consumption enabled Thinkpower monitoring solution.And built-in anti-backflow limit is available to controlexport power.
|
Parameter Category |
Parameter Name |
S1000TL |
S1500TL |
S2200TL |
S3000TL |
S4400TL |
S5000TL |
S6000TL |
|
DC Side / Input Parameters |
DC maximum power (W) |
1000 |
1500 |
2200 |
3000 |
4400 |
5000 |
6000 |
|
Maximum DC voltage (V) |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
|
|
System standard battery voltage (Vdc) |
60/70 |
70/100 |
70/100 |
70/100 |
70/100 |
70/100 |
70/100 |
|
|
MPPT voltage range (Vdc) |
70 - 500 |
100 - 500 |
100 - 500 |
100 - 500 |
100 - 500 |
100 - 500 |
100 - 500 |
|
|
Maximum current (A) |
2A |
3A |
4A |
6A |
10A |
10A |
10A |
|
|
Maximum short-circuit current (A) |
25A |
35A |
50A |
60A |
100A |
100A |
100A |
|
|
MPPT tracker number |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
|
AC Side / Output Parameters |
Nominal output power (W) |
1000 |
1500 |
2200 |
3000 |
4400 |
5000 |
6000 |
|
Maximum output power (W) |
1100 |
1650 |
2420 |
3300 |
4840 |
5500 |
6600 |
|
|
Nominal output voltage range (V) |
200 - 240 |
200 - 240 |
200 - 240 |
200 - 240 |
200 - 240 |
200 - 240 |
200 - 240 |
|
|
Power grid frequency range ( Hz) |
50Hz (±0.5 Hz auto-adjustment) |
50Hz (±0.5Hz auto -adjustment) |
50Hz (±0.5Hz auto -adjustment) |
50Hz (±0.5Hz auto -adjustment) |
50Hz (±0.5Hz auto -adjustment) |
50Hz (±0.5Hz auto -adjustment) |
50Hz (±0.5Hz auto -adjustment) |
|
|
Maximum output current (A) |
4.5 |
6.75 |
9 |
11.25 |
18 |
20.625 |
24.75 |
|
|
Power grid connection method |
Single phase |
Single phase |
Single phase |
Single phase |
Single phase |
Single phase |
Single phase |
|
|
Total electrical distortion (THD) |
+1.5% |
+1.5% |
+1.5% |
+1.5% |
+2.5% |
+2.5% |
+2.5% |
|
|
Power factor |
-1% (from 0.8 lagging to 0.8 leading) |
-1% (from 0.8 lagging to 0.8 leading) |
-1% (from 0.8 lagging to 0.8 leading) |
-1% (from 0.8 lagging to 0.8 leading) |
-1% (from 0.8 lagging to 0.8 leading) |
-1% (from 0.8 lagging to 0.8 leading) |
-1% (from 0.8 lagging to 0.8 leading) |
|
|
Efficiency |
Maximum conversion efficiency |
97.2% |
97.2% |
97.4% |
97.2% |
97.2% |
97.2% |
97.2% |
|
European efficiency |
97.0% |
97.0% |
97.1% |
97.2% |
97.3% |
97.2% |
97.2% |
|
|
MPPT efficiency |
99.9% |
99.9% |
99.9% |
99.9% |
99.9% |
99.9% |
99.9% |
|
|
Safety and Protection |
DC reverse polarity protection |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
|
Anti-islanding/overvoltage protection |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
|
|
Short circuit protection |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
|
|
Leakage current protection |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
|
|
Grid connection grounding fault monitoring |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
|
|
QCI (Quick Current Interruption) protection |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
|
|
General Parameters |
Dimensions (L×W×H/mm) |
300×200×104 |
370×318.5×105.8 |
370×318.5×105.8 |
370×318.5×105.8 |
370×318.5×105.8 |
370×318.5×105.8 |
370×318.5×105.8 |
|
Weight (kg) |
8 |
10 |
10 |
10 |
10 |
10 |
10 |
|
|
Embedded DC Switch |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
|
|
High power consumption (W) |
+0.2 |
+0.2 |
+0.2 |
+0.2 |
+0.2 |
+0.2 |
+0.2 |
|
|
Isolation type |
Transformerless |
Transformerless |
Transformerless |
Transformerless |
Transformerless |
Transformerless |
Transformerless |
|
|
Protection level |
IP65 (IEC60529) |
IP65 (IEC60529) |
IP65 (IEC60529) |
IP65 (IEC60529) |
IP65 (IEC60529) |
IP65 (IEC60529) |
IP65 (IEC60529) |
|
|
Operating temperature (°C) |
-25~+60 |
-25~+60 |
-25~+60 |
-25~+60 |
-25~+60 |
-25~+60 |
-25~+60 |
|
|
Installation height (m) |
≤2000m no power derating |
≤2000m no power derating |
≤2000m no power derating |
≤2000m no power derating |
≤2000m no power derating |
≤2000m no power derating |
≤2000m no power derating |
|
|
Sound level ( dB) |
≤25 |
≤25 |
≤25 |
≤25 |
≤25 |
≤25 |
≤25 |
|
|
show |
Graphic LCD |
Graphic LCD |
Graphic LCD |
Graphic LCD |
Graphic LCD |
Graphic LCD |
Graphic LCD |
One step to find us,we will respond within 24 hours.
More Contact Details
008613738639386
[email protected]